AMERICAN CRS EQUIPMENT · CABINETS
Q800 rectifier cabinets
A cabinet platform for Sirius and Quasar units
Bring compatible rectifiers and their distribution equipment into one organized cabinet. The Q800 gives American CRS customers a common platform for multi-output installations, with cabinet size and cooling selected around the equipment on the line.
25U
Cabinet size
35U
Cabinet size
45U
Cabinet size
Select cabinet size around the rectifier mix, output count, distribution equipment and service access.
Build the cabinet around your process.
The Q800 houses compatible S075, Q100, Q150R and Q300 rectifiers. Power and water distribution can be organized within the cabinet, while front access and a top communication entry keep the installation practical to connect and service. Specify the rectifiers and cabinet package together.
Multiple outputs
Configurations support up to eight separate outputs. The number of rectifiers and outputs depends on the selected units and cabinet layout.
Air or water cooling
Choose the cooling arrangement for the installed rectifiers and available facility services.
Organized distribution
Plan power entry, branch protection, water connections and communications as part of one installation.
Three cabinet sizes. One organized system.
Choose the rack size after defining the rectifier mix, distribution equipment and access requirements. The published output limit does not specify the capacity of every size or model combination.
Q800 25U
The shortest illustrated cabinet. Overall illustrated height: 54.92 inches.
Q800 35U
The middle illustrated cabinet. Overall illustrated height: 72.44 inches.
Q800 45U
The tallest illustrated cabinet. Overall illustrated height: 89.92 inches.
Compatible rectifiers
These are the specified rectifier models for the Q800 platform. Cabinet capacity still depends on the selected units and layout. Q150 compatibility refers specifically to Q150R.
Technical specifications
Cabinet features below describe the Q800 platform. Electrical output ratings come from the installed rectifiers.
Specification
Q800 cabinet / configuration
Cabinet platform
Equipment type
Cabinet for compatible Sirius and Quasar rectifiers
Rack sizes
25U / 35U / 45U
Cooling
Air or water, selected with the installed rectifiers
Separate outputs
Up to 8, configuration dependent
Enclosure protection
IP32 / IP42, configuration dependent
Communication entry
Top
Service access
Front door
Distribution & connections
Power connections
Top or bottom arrangements
Branch protection
Fuses on each branch
Water connections
Front or rear arrangements
Water instrumentation
Flow and temperature meters available
Confirm rectifier type, quantity, output count and distribution layout before selecting cabinet size. Up to eight outputs is a platform limit, not a guarantee that eight of every rectifier model fit in every cabinet.
Dimensions & drawings
Illustrated cabinet dimensions are shown in width × height × depth order. The U designation identifies the rack size; use the overall cabinet heights below when planning floor space.
25U illustrated cabinet
23.62 in
Width
54.92 in
Height
31.50 in
Depth
Illustrated cabinet dimensions. Confirm the final equipment layout, connection space and service clearances.
35U illustrated cabinet
23.62 in
Width
72.44 in
Height
31.50 in
Depth
Illustrated cabinet dimensions. Confirm the final equipment layout, connection space and service clearances.
45U illustrated cabinet
23.62 in
Width
89.92 in
Height
31.50 in
Depth
Illustrated cabinet dimensions. Confirm the final equipment layout, connection space and service clearances.
The linked CRS drawing is labeled in millimeters; the editable cabinet dimensions above are converted to inches.
Options & accessories
Select the cabinet arrangement and metering around the installation. Confirm the complete equipment schedule with American CRS.
Options
- Cabinet size. Select 25U, 35U or 45U around the equipment schedule.
- Cooling arrangement. Specify an air- or water-cooled installation appropriate to the rectifiers.
- Power entry. Select the top or bottom connection arrangement.
- Water routing. Front and rear connection arrangements are available for the water distribution system.
Metering accessories
- Water-flow metering. Available for the water distribution system.
- Water-temperature metering. Available for the water distribution system.
A closer look at the Q800
Product renders show the enclosure and distribution details. The selected rectifiers, connections and cabinet arrangement determine the final installation.
1. Door closed 2. Door open 3. Water distribution 4. Power distribution




CONFIGURE YOUR Q800
Build one cabinet around your line.
Tell American CRS the rectifier models, quantity, number of separate outputs, cooling services and preferred cabinet size. We’ll help define the Q800 equipment and distribution layout for your installation.